г. Рязань, проезд Яблочкова, д. 5, к. 36

Two-Electrode Spark Gaps (Неуправляемые разрядники)

Two-Electrode Spark Gaps by Pulsetech are  robust gas-discharge tubes hermetically sealed in a metal-ceramic envelope. The tunes does not contain any toxic or radioactive substances.

The design is protected by russian patent #108224, with priority from November 2009.

Typical applications:

  • Voltage Surge Protection Circuits
  • High-Energy Switching, including Medical Lithotripcy and Shock-Wave Applications
  • Flash X-ray Equipment
  • Transmitter Protection
  • Relaxation Generator Circuits

 

Swicthing and protection spark gaps

Part Name

Static Breakdown Voltage, kV1

Maximal Peak Current (single discharge, 8/20 us), kA2

Maximal Charge Transfer, single discharge, 8/20 us, C

Data Sheet

LA2M

0.5-5

5

0.0001

LA22

1.0-10

5

0.005

 -

LA26

1.0-20

20

0.010

-

LA30

3.0-30

2

0.5

-

LA86

4-50

200

1

-

LA96

100-250

50

1

-

RK83

0.6-6

15

0.01

-

RK84

1-15

15

0.05

-

RK85

5-50

15

0.05

-

RK86

5-50

25

0.5

-

RK89

20-250

1

0.5

-

RK90

10-200

30

1

-

RK24.3

10-150

15

0.5

-

Notes:

1) Device breakdown voltage is signified by numerals (expressed in thousands of volts), after the hyphen.

2) the peak current can be higher with reduction in service life expectancy.

Switching sharpeners

Part name

Dynamic Breakdonw Voltage, kV 1,2

Peak Current, single discharge, kA

Charge Transfer, single discharge, C

Data sheet

RO89

200-300

1

0,1

-

RO90

100-200

1

0,01

 -

RO600

300-600

5

0.1

-

Notes:

1) the tube can be made for operating voltage in the given range, this is signified by numerals following the hyphen after the part name and expressed in thousands of voltage

2) the given voltage is a dynamic value, with rate of rise  10 kV/ns approximately

Контакты